Vulnerability alert · 19 Nov 2026
[email protected], through the VMware Directory Service on TCP port 2012. Broadcom fixed it on 19 November 2026 in VMSA-2026-0009.If you run vCenter 8.0, 9.0 or 9.1 below the fixed builds, an attacker who can reach it on the network can log in as the SSO administrator without a password. Broadcom's fix shipped on 19 November 2026, with no workaround, and Broadcom itself calls it an emergency change. Mandiant reports the flaw was already used in targeted espionage before the fix. Patch today, then check whether someone got in first: rogue SSO admins, SSH switched on and off, and forged SAML tokens survive the patch.
CVE-2026-123890 is an authentication bypass in the VMware Directory Service (vmdir), the identity store behind vCenter single sign-on. Mandiant's analysis, as summarised by SecurityOnline, says the RPC interface on TCP port 2012 discloses a Secure Remote Password session key. An attacker uses it to get an [email protected] session without the password (SecurityOnline). It is a different bug from July's vmdir flaw CVE-2026-59309: the attack tool worked against servers already patched for that one.
The same advisory, VMSA-2026-0009, fixes four lower-rated issues: SQL injection (CVE-2026-123891), command injection (CVE-2026-123892) and privilege escalation (CVE-2026-123893) in SDDC Manager, and a SAML signature bypass in VMware Tools for Windows (CVE-2026-123894). ESXi is not affected, nor are NSX, VCF Operations, VCF Automation, Workstation or Fusion (Broadcom VMSA-2026-0009 Q&A).
One trap from Broadcom's FAQ: vCenter 8.0 U3m and 9.0.2.0200 block a later upgrade to VCF 9.1.1, so Broadcom advises going to VCF 9.1.2 when it ships. Don't let that delay the fix. Running VMs keep running while vCenter is updated.
SecurityOnline reports that Mandiant and Google Threat Intelligence attribute in-the-wild exploitation to ARMORY CASTLE, a suspected China-nexus espionage group previously tracked as UNC5221. The exploitation dates to early September 2026, and the group's exploit tool BONESAW carries a July build timestamp. NHS England's cyber alert also describes it as a zero-day. Broadcom's advisory doesn't comment on exploitation, and The Hacker News, published earlier, said Broadcom had reported no attacks (The Hacker News). Treat it as exploited. Check the CVE lookup for when CISA adds it to KEV.
The reported intrusion shows what happens after the bypass. It started with ARMORY CASTLE's BeyondTrust Remote Support zero-day (CVE-2026-102764, in CISA KEV since 16 October). The group moved to an internal Linux appliance without EDR and scanned for port 2012. It used BONESAW to copy the directory database, steal the SAML signing key and create an SSO admin. It then forged SAML logins ("Golden SAML") to bypass MFA. Finally it enabled SSH on vCenter, took its master key and database credentials, and disabled SSH again.
SSH-2.0-pulsesecure_23345.vCenter controls every VM, including domain controllers and anything in PCI scope, so compromising it is equivalent to compromising the whole environment. For PCI DSS this is a critical vulnerability on a system that is in scope or connected to it, and the management network must be segmented from users. For NIS2 and DORA, a confirmed compromise of the virtualisation layer is very likely a significant incident; the incident clock calculates the reporting deadlines. Keep evidence of the patch date, the hunt you ran and what it found.
vCenter 9.1.1.0200, 9.0.2.0200 and 8.0 U3m, released on 19 November 2026; VCF 5.x customers apply 8.0 U3m with SDDC Manager 5.2.5. vCenter 7.0 and older are out of support and should be presumed affected.
No. Broadcom says ESX/ESXi is not affected by VMSA-2026-0009. The flaw is in vCenter's directory service, but an attacker who controls vCenter can still manage every ESXi host attached to it.
Broadcom lists none, so patching is the fix. Restricting network access to vCenter, including TCP port 2012, to trusted management hosts reduces exposure while you schedule it.
We patch and segment the management plane, hunt for rogue SSO admins and forged SAML activity, and help you rotate the identity keys safely, with the evidence your PCI DSS or NIS2 auditor will ask for.
Request a quote →